Measures G,
INR, SNR, Leq, LAeq, LCeq, BR(L)
Magnitude spectrum (linear and -3dB/octave), EDT, T10,
T20,
T30,
Tx,
RT, BR(RT), C30,
C50,
C80,
Cx,
D50,
Dx,
H, Ts, LF, LFC, IACC80, IACCx, Support, STI, % ALC, RASTI, STITEL, STIPA, In-situ
reflection and absorption.
Conforms
to ISO 3382 and IEC 60268-16 standards and supports ISO 3741 and
EN 1793-5 standards
Included
digital 1/1 and 1/3 octave band filters are fully IEC 1260
compliant
Supports
scale model measurements and auralisation
User
friendly and fast: from start-up through first measurement in
only 3 mouse clicks
High
signal to noise ratio, using internally generated MLS signals
with optional pink or speech filters
High
loudspeaker system output power, using internally generated swept sines
with optional pink, speech or bandlimiting filters
Exponentially
swept sines for high tolerance against system non-linearities
and time-variance.
Real
time averaging of up to 1000 recordings
Portable
light-weight measurement set, using notebook PC and blank pistol
Automated
measurements reduce the total time required for a measurement
session.
|
|
Measure
impulse response in occupied rooms, using music as sound source.
Supports
open loop measurements using a CD or MP3 player to play back an
MLS or sweep stimulus.
Level
calibration and speech filters for accurate speech
intelligibility measurements with the option to add artificial
noise spectra.
Calibration
functions allow for the use of standard Windows compatible sound
devices and low cost hardware, without the need to manually
set input and output levels.
Supports
selection from multiple sound devices in a single system
Noise
compensated reverberation time calculations
Reverse
filtering technique enables accurate short reverberation time
measurement, such as in studios and building structures (loss
factor)
Waveform
editing with unlimited undo
Uses
standard WAV and ASCII files as well as MLSSA TIM files
Export
to ODEON or MATLAB.
Calculates
and graphically displays statistics over multiple measurements
(mean, standard deviation, min-max)
Parameter
graphs can be printed, saved as text files or copied to the
clipboard for use in reports
Displays
waterfall plots and spectrograms
Runs
on Windows 2000/XP/Vista
|